When it's time for a heart-to-heart conversation with your surgical valve patients, consider these tools to help get the dialogue going.

INSPIRIS-RESILIA aortic valve
February 20, 2024
INSPIRIS RESILIA aortic valve
Website
INSPIRIS
Aortic
RESILIA
Informed Discussion Guide
March 01, 2024
Informed Discussion Guide: Surgical aortic valve replacement
Website
Patient
KONECT RESILIA aortic valved conduit
March 01, 2024
KONECT RESILIA aortic valved conduit
Website
KONECT
Conduit
Aortic
RESILIA
Inspiring Results RESILIA Tissue Clinical Data Page
March 01, 2024
Inspiring Results RESILIA Tissue Clinical Data Page
Website
Tissue
RESILIA
Data
Clinical
MITRIS RESILIA aortic valve
March 01, 2024
MITRIS RESILIA aortic valve
Website
MITRIS
Mitral
RESILIA
Timely Intervention Fact Sheet
March 01, 2024
Timely Intervention Fact Sheet
Factsheet
Timely
Therapy
Anticoagulation Considerations for Choosing a Tissue or Mechanical Heart Valve
March 01, 2024
Anticoagulation Considerations for Choosing a Tissue or Mechanical Heart Valve
Factsheet
Mechanical
Tissue
Anticoagulation
Aortic Regurgitation Website
March 01, 2024
Aortic Regurgitation Website
Website
Aorticregurgitation
PP--US-7494-Transcatheter-aortic-valve-with-RESILIA-tissue-704x480
March 01, 2024
Transcatheter aortic valve with RESILIA tissue
Website
TAVR
SAPIEN
RESILIA
Surgical Heart Valve Replacement in Women of Childbearing Age
March 01, 2024
Surgical Heart Valve Replacement in Women of Childbearing Age
Tissue
Women
Mechanical
Pregnant
PDF thumbnail
March 01, 2024
Surgical Tissue Valve Guide for Your Patients
Tissue
SAVR
Guide
Patient
RESILIA
Brochure
Important safety information

Important safety information

RESILIA Tissue Devices

Indications: INSPIRIS RESILIA Aortic Valve - For use in replacement of native or prosthetic aortic heart valves. KONECT RESILIA Aortic Valved Conduit - For use in replacement of native or prosthetic aortic heart valves and the associated repair or replacement of a damaged or diseased ascending aorta. MITRIS RESILIA Mitral Valve - For use in replacement of native or prosthetic mitral heart valves.

Contraindications: There are no known contraindications with the use of these RESILIA tissue heart valve devices.

Complications and Side Effects: INSPIRIS RESILIA Aortic Valve - Thromboembolism, valve thrombosis, hemorrhage, hemolysis, regurgitation, endocarditis, structural valve deterioration, nonstructural dysfunction, stenosis, arrhythmia, transient ischemic attack/stroke, congestive heart failure, myocardial infarction, any of which could lead to reoperation, explantation, permanent disability, and death. Additional adverse events potentially associated with the use of polyester vascular grafts in the KONECT RESILIA AVC include hemorrhage, thrombosis, graft infection, embolism, aneurysm, pseudoaneurysm, seroma, occlusion (anastomotic intimal hyperplasia), immunological reaction to collagen (shown to be a weak immunogen; infrequent, mild, localized and self-limiting), intimal peel formation, and conduit dilatation. MITRIS RESILIA Mitral Valve - Thromboembolism, valve thrombosis, hemorrhage, hemolysis, regurgitation, endocarditis, structural valve deterioration, nonstructural dysfunction, stenosis, arrhythmia, transient ischemic attack/stroke, congestive heart failure, myocardial infarction, ventricular perforation by stent posts, any of which could lead to reoperation, explantation, permanent disability, and death.

Warnings: INSPIRIS RESILIA Aortic Valve - DO NOT ADJUST THE VALVE DIAMETER BY EXPANDING THE BAND PRIOR TO OR DURING IMPLANTATION OF THE SURGICAL VALVE. The expandable band is not designed to allow for compression or expansion during implantation of the surgical valve. This will cause damage to the valve and may result in aortic incompetence. DO NOT PERFORM STAND-ALONE BALLOON AORTIC VALVULOPLASTY PROCEDURES ON THIS VALVE FOR THE SIZES 19 – 25 mm as this may expand the valve causing aortic incompetence, coronary embolism or annular rupture. Valve-in-valve sizing in the INSPIRIS valve has only been tested with specific Edwards transcatheter heart valves. Use of other transcatheter valves may result in embolization of transcatheter devices anchored within or result in annular rupture.

CAUTION: Federal (USA) law restricts these devices to sale by or on the order of a physician. See instructions for use for full prescribing information.