The ForeSight Jr sensor is different by design – giving you actionable insights to protect

Wavelength icon
5 wavelengths
+
Sensor design icon
Sensor design
+
Algorithm icon
Site-specific algorithms
=
Bullseye icon
Trusted performance
Sensor icon

Exclusive fifth wavelength

Because other systems use only two, three, or four wavelengths of near infrared light (NIRS), patient differences in bilirubin and meconium concentrations can cloud the accuracy – and therefore the reliability – of oxygenation measures.

Only the ForeSight system incorporates a fifth wavelength of NIRS measuring at 685 nm to account for these patient differences and enable reliable StO2 measures from patient to patient.

Wavelength icon

Unique sensor design

With three sensor models and design features intended to be gentle on delicate skin, as well as allow its use across all pediatric patients sizes.

Algorithm icon

Site-specific algorithms1

While some systems are only validated to SjvO2, the ForeSight system algorithms are calibrated and validated for both cerebral and somatic regions:

  • Cerebral (StO2) tissue oximetry is calibrated and validated to jugular bulb venous oxygen saturation (SjvO2)
  • Somatic (StO2) tissue oximetry is calibrated and validated to central venous oxygen saturation (ScvO2)

Tissue oximetry measures you can trust and treat to

Every patient and their needs are different. The ForeSight Jr sensor was designed to accommodate each patient’s unique anatomy and physiology to deliver cerebral tissue oximetry values that you can depend on.

Patient using The ForeSight tissue oximetry system

Penetrate to the appropriate depth

Ensuring the appropriate penetration depth for your pediatric patient’s size is important to achieving accurate, actionable oximetry readings.

The ForeSight system offers a variety of sensor sizes and two modes of penetration – 1.25 cm and 2 cm – so that you can ensure you’re measuring the appropriate penetration depth for your patient’s anatomy.

ForeSight Jr medium sensor

ForeSight Jr
medium sensor

Cerebral – Patients ≥ 3kg
Non-cerebral – Patients ≥ 3kg

ForeSight Jr small sensor

ForeSight Jr
small sensor

Cerebral – Patients <8kg
Non-cerebral – Patients <5kg

ForeSight Jr small non-adhesive
                        sensor

ForeSight Jr
small non-adhesive sensor

Cerebral – Patients <8kg
Non-cerebral – Patients <5kg

Boy with small sensor

Use on the most delicate skin

With cushioned patient interfaces and CoolLight LED technology designed to reduce heat generation, the ForeSight Jr sensor is designed to be gentle on skin.

The ForeSight Jr sensor also maintains accuracy when used with a Tegaderm™ skin barrier.

Edwards clinical education

Comprehensive education empowering clinical advancement

With a long-term commitment to improving the quality of care for surgical and critical care patients through education, Edwards clinical education meets you no matter where you are in the learning process – with a continuum of resources and tools that continuously support you as you solve the clinical challenges facing you today, and in the future.

Related products

ForeSight tissue oximetry system for adults

The ForeSight sensor for adults also accounts for patient-to-patient differences, delivers absolute StO2 values without requiring a preinduction baseline and integrates with the HemoSphere platform for an all-in-one view of pressure and flow.

Learn more
ForeSight tissue oximetry system for adults

HemoSphere advanced monitoring platform

HemoSphere advanced monitoring platform offers full-range device compatibility for proactive decision support across a diversity of patient profiles and across care settings.

Explore the HemoSphere platform
HemoSphere

Let us help you

Do you have feedback about our products? Click here

Reference
  1. Benni, Paul. Validation of the Edwards FORE-SIGHT Absolute Tissue Oximeter Module for Cerebral and Somatic Tissue Oxygen Saturation (StO2%) in Adults, Transitional Adolescents in Pediatric Subjects. 2018;1-32.

For professional use

For professional use

For a listing of indications, contraindications, precautions, warnings, and potential adverse events, please refer to the Instructions for Use (consult eifu.edwards.com where applicable).

Edwards Lifesciences devices placed on the European market meeting the essential requirements referred to in Article 3 of the Medical Device Directive 93/42/EEC bear the CE marking of conformity.

Please update your browserClose this window

Please update to a current version of your preferred browser, this site will perform effectively on the following:

Unable to update your browser?

If you are on a computer, that is maintained by an admin and you cannot install a new browser, ask your admin about it. If you can't change your browser because of compatibility issues, think about installing a second browser for browsing and keep this old one for compatibility