Closed Blood Sampling Closed Blood Sampling

Closed blood sampling

Effective patient blood management

Closed blood sampling

Effective patient blood management

VAMP Optima System

VAMP Optima system

The VAMP Optima system is an OR friendly closed blood sampling solution compatible with the FloTrac sensor which allows for continuum of care for hemodynamically unstable patients that require frequent blood sampling in the perioperative setting.

  • 84 in (213 cm) of pressure tubing and two sample sites offer flexibility for OR and ICU use
  • Large 12 cc reservoir provides optimized clearing volume
  • Safety locking mechanism on the reservoir to prevent autofilling
  • Convenient single hand operation for simplified sampling and clearing volume reinfusion
  • One step flushing
  • Intuitive use and clear user interface with fluid path icons
  • nDEHP tubing to limit potentially harmful phthalate exposure
  • Two sample site locations allow for sampling outside the sterile field in the OR and close to the patient in the ICU setting

VAMP Optima kits with LASS (Luer Activated Sampling Site) provide the following benefits

  • No excessive damping of the blood pressure signal with the rotating handle that can direct the flow away from the valve
  • Time and labor saving in blood aspiration mode with a single flush after blood sampling (in comparison with two boluses required with a regular stopcock)
  • Minimal blood residues that may help prevent contamination and reduce infection rates

VAMP Optima LASS Brochure

VAMP Optima Z-site Brochure

LASS Quick Reference Guide

Z-site Quick Reference Guide

Model numbers

ModelDescriptionQty
VOPTIMA VAMP Optima with Z-site sample site 10
VOPTIMAL VAMP Optima with LASS sample site 10
MHD8VZ FloTrac sensor kit with VAMP Optima system and z-site sample sites 1
MHD8VZ5 FloTrac sensor kit with VAMP Optima system and z-site sample sites 5
MHD8VRL FloTrac sensor kit with VAMP Optima system with LASS sample sites and red striped tubing 1
MHD8VRL5 FloTrac sensor kit with VAMP Optima system with LASS sample sites and red striped tubing 5
MHD8VZTW FloTrac sensor double kit with TruWave DPT, VAMP Optima system with Z-site sample sites 5
MHD8VLTW FloTrac sensor double kit with TruWave DPT, VAMP Optima system with LASS sample sites 5
VAMP Adult System

Safe, simple and reliable closed blood sampling for effective patient blood management.

  • The VAMP adult system is designed to reduce infection and blood waste associated with traditional blood sampling
  • 5 cc reservoir designed for safe and convenient blood sampling in environments where close proximity to the patient is desired
  • For use with disposable pressure transducers and for connection to central line catheters and arterial catheters
  • Versatile design can be pole mounted on a backplate or used as an arm mount
  • Z-site self-sealing sample port reduces blood buildup for collection of undiluted samples and improves infection control compared to traditional sampling methods
VAMP Adult Closed Blood Sampling System

MODEL NUMBERS

ModelDescriptionUnit of Measure
48VMP106   6" sampling kit, sample site, reservoir and two shut-off valves CS(20)
48VMP120   20" sampling kit, sample site and arm reservoir CS(20)
48VMP160   60" sampling kit, sample site and arm reservoir CS(20)
48VMP172   72" sampling kit, sample site and arm reservoir CS(20)
48VMP184   84" sampling kit, sample site and arm reservoir CS(20)
48VMP260   60" sampling sit, sample site and pole-mount reservoir CS(20)
48VMP272     72" sampling kit, sample site and pole-mount reservoir CS(20)
48VMP284     84" sampling kit, sample site and pole-mount reservoir CS(20)
48AVMP  VAMP system anesthesia kit, 68" sampling kit with male / female connector CS(20)
VAMP Plus System

Sampling flexibility between surgery and intensive care

  • Large 12 cc reservoir provides optimized clearing volume
  • Choice of one or two Z-site sample sites for flexibility in perioperative settings
  • Convenient one-handed operation simplifies sampling and clearing volume reinfusion
  • Available individually or integrated into your disposable pressure transducer kit

Product Brochure

Quick Reference Guide

VAMP Plus Closed Blood Sampling System

MODEL NUMBERS

ModelDescriptionUnit of Measure
VP1    VAMP Plus system reservoir with 60" patient tubing and one sample site located 55" from the patient CS(10)
VP2   VAMP Plus system reservoir with 60" patient tubing and two sample sites located 13" and 55" from the patient CS(10)
VAMP Jr System
Safety and accuracy for your smallest patients
  • Designed to meet the volume-critical requirements of pediatric patients
  • Smaller 3 cc reservoir optimizes clearing volumes, providing undiluted, accurate blood samples
  • Graduated “cc” markings aid in selecting appropriate clearing volume for each patient
  • Special contamination hood helps reduce infection risk
  • Variety of tubing lengths to accommodate patient size requirements

Product Brochure

Quick Reference Guide

VAMP Jr Closed blood sampling System

MODEL NUMBERS

ModelDescriptionUnit of Measure
VMP306   6" kit with 3 cc reservoir and 2 sample sites CS(20)
VMP406   6" kit with 3 cc reservoir and 1 sample site CS(20)
VMP426   26" kit with 3 cc reservoir and 1 sample site CS(20)
VMP448   48" kit with 3 cc reservoir and 1 sample site CS(20)
VAMP Flex System

Sampling flexibility between surgery and intensive care on an offline system.

  • Large 10 cc reservoir provides optimized clearing volume
  • Choice of one or two Z-site sample sites for flexibility in perioperative settings
  • Offline version
  • Available individually or integrated into your disposable pressure transducer kit
Accessories

MODEL NUMBERS

Model DescriptionUnit of Measure
VMP400 VAMP system needleless Cannula CS(200) 
VMP600  VAMP system blood transfer unit (BTU) for sample transfer to vacuum tubes CS(50) 
VMP700  VAMP system direct draw unit for direct line blood sampling CS(50) 

Related Products

Contact us

For Professional Use

For Professional Use

See instructions for use for full prescribing information, including indications, contraindications, warnings, precautions and adverse event.