Edwards Lifesciences Clot Management Edwards Lifesciences Clot Management

Count on the experience of the first name in clot management

Fogarty® arterial embolectomy catheter

Removal of fresh, soft emboli and thrombi from vessels in the arteries of the non-central circulatory system

  • Hand-tied using a recessed winding technique to secure balloon to catheter
  • Balloon exhibits a symmetry that exerts uniform contact with vessel walls for even pressure and
    precise traction
  • Rounded tip promotes easy insertion for reduced trauma

Fogarty arterial embolectomy catheter (pouches, 5 pack)

ModelLength (cm)Catheter Size (F)Inflated Balloon Diameter (mm)Max. Size of Deflated Balloon (F)Max. Gas Capacity (ml)Max. Liquid Capacity (ml)Max. Recommended Pull Force on Inflated Balloon (kg)Compatible Guidewire (mm)
120602FP 60 2 4 3.4 0.2 - 0.23 -
120403FP 40 3 5 4.3 0.6 0.20 0.3 -
120403FSP 40 3 5 4.3 0.6 0.20 0.3 -
120803FP 80 3 5 4.3 0.6 0.20 0.3 -
120803FSP 80 3 5 4.3 0.6 0.20 0.3 -
120404FP 40 4 9 5.0 1.7 0.75 .68 -
120804FP 80 4 9 5.0 1.7 0.75 .68 -
120805FP 80 5 11 6.0 3.0 1.50 0.9 -
120806FP 80 6 13 7.0 4.5 2.00 1.13 -
120807FP 80 7 14 8.0 5.0 2.50 1.59 -

Edwards Fogarty catheter rack

  • This rack is intended to be wall-mounted
  • After wall-mounting it can be used to hold Fogarty catheters
  • Model number CV6000

Fogarty Fortis arterial embolectomy catheter

Removal of fresh, soft emboli and thrombi from vessels in the arteries of the non-central circulatory system

  • Can withstand greater pull-force than the Fogarty arterial embolectomy catheter
  • The addition of barium sulfate to the catheter tubing provides radiopacity

Fogarty Fortis arterial embolectomy catheter (pouches, 5 pack)

ModelUsable Length (cm)Catheter Size (F)Inflated Balloon Diameter (mm)Max. Size of Deflated Balloon (F)Max. Gas Capacity (ml)Max. Liquid Capacity (ml)Max. Recommended Pull Force (kg)Compatible Introducer (f)Compatible Guidewire (mm)
120404FFP 40 4 9 5.0 1.7 0.75 - 5 -
120804FFP 80 4 9 5.0 1.7 0.75 - 5 -

Edwards silicone embolectomy catheter

When you are seeking additional solutions for clot management

  • Silicone balloon and catheter body
  • Stainless steel reinforced catheter body
  • Available in tube or flat packaging

latex

Flat PacksCatheter Size (F)Catheter Length (cm)Max. Balloon Inflation CapacityApproximate Balloon Diameter (mm)
NL2EMB40 2 40 0.05 ml 4
NL2EMB60 2 60 0.05 ml 4
NL3EMB40 3 40 0.10 ml 5
NL3EMB80 3 80 0.10 ml 5
NL4EMB40 4 40 0.50 ml 9
NL4EMB80 4 80 0.50 ml 9
NL4EMB100 4 100 0.50 ml 9
NL5EMB40 5 40 0.75 cm 11
NL5EMB80 5 80 0.75 cm 11
NL6EMB80 6 80 1.25 cm 13
NL7EMB80 7 80 2.00 cm 14

Fogarty thru-lumen embolectomy catheter

Multi-use guidewire-compatible design enables removal of fresh, soft emboli and thrombi from vessels in the arterial system as well as temporary occlusion of blood vessels, infusion of fluids, and blood sampling

    • Fogarty balloon conforms to the vessel to maximize clot removal while minimizing trauma
    • Provides the solution for distal thrombus removal in the arterial system
    • The addition of barium* to the catheter shaft material and stainless steel markers proximal and distal to the balloon provide radiopacity*

*3F thru-lumen embolectomy catheter body does not include barium.

ModelUsable Length (cm)Catheter Size (F)Inflated Balloon Diameter (mm)Max. Size of Deflated Balloon (F)Max. Gas Capacity (ml)Max. Liquid Capacity (ml)Max. Recommended Pull Force on Inflated Balloon (kg)Compatible Introducer* (f)Compatible Guidewire (mm)
12TLW403F 40 3 5 4.5 0.4 0.15 0.32 4.5 0.046
12TLW803F 80 3 5 4.5 0.4 0.15 0.32 4.5 0.046
12TLW1203F 120 3 5 4.5 0.4 0.15 0.32 4.5 0.046
12TLW404F 40 4 9 5.0 1.2 0.50 .68 5 0.064
12TLW804F 80 4 9 5.0 1.2 0.50 .68 5 0.064
12TLW405F35 40 5.5 11 6.0 1.7 0.90 .91 6 0.089
12TLW805F35 80 5.5 11 6.0 1.7 0.90 .91 6 0.089
12TLW406F 40 6 13 7.0 2.3 1.40 1.13 7 0.089
12TLW806F 80 6 13 7.0 2.3 1.40 1.13 7 0.089
12TLW807F 80 7 14 8.0 2.8 1.60 1.59 8 0.097
*Ease of introducing the catheter through hemostasis valve may vary among manufacturers.

Fogarty Corkscrew catheter

Removal of emboli and thrombi from either native vessels or synthetic grafts in the arterial system

  • For extracting thrombus that is too resistant for an elastomeric balloon
  • Corkscrew design increases the surface area for entrapping fibrous material
  • Radiopaque and flexible

ModelUsable Length (cm)Catheter Size (F)Membrane Diameter Max. Extended (mm)Membrane Diameter Max. Retracted (mm)
140806 80 4 2.7 6
140808 80 5 3.1 8
1408010 80 6 3.3 10

Fogarty graft thrombectomy catheter

Designed for removing organized thrombus and adherent thrombotic material from synthetic bypass grafts, specifically, AV fistulas for dialysis access and grafts for iliofemoral bypass

  • For extracting thrombus too resistant for an elastomeric balloon
  • Provides a larger diameter range than the Fogarty adherent clot catheter
  • The pulling force can be varied by adjusting the diameter
ModelLength (cm)Catheter Size (F)Membrane/Spiral Diameter Max. Extended (mm)Membrane/Spiral Diameter Max. Retracted (mm)
160245F 50 5 5.0 16
160246F 50 6 6.0 18

Fogarty venous thrombectomy catheter

Designed for removing thrombi in the venous system

  • The long, soft tip facilitates advancement past the venous valves without undue trauma

ModelUsable length (cm)Catheter size (F)Inflated balloon diameter (mm)Max. size of deflated balloon (F)Max. gas capacity (ml)Max. liquid capacity (ml)Max. recommended pull force (kg)Compatible introducer (f)Compatible guidewire (mm)
320806F 80 6 12 7.7 3.0 1.50 - - -
320808F 80 8 13 8.8 4.5 2.25 - - -
32080810F 80 8 19 10.0 8.0 4.00 - - -


Contact a sales rep

Do you have feedback about our products? Click here

For professional use

For professional use

For a listing of indications, contraindications, precautions, warnings, and potential adverse events, please refer to the Instructions for Use (consult eifu.edwards.com where applicable).

Edwards Lifesciences devices placed on the European market meeting the essential requirements referred to in Article 3 of the Medical Device Directive 93/42/EEC bear the CE marking of conformity.