Closed blood sampling
Effective Patient Blood Management
To minimize blood loss during sampling, Edwards Lifesciences' VAMP closed blood sampling systems incorporate an in-line reservoir that allows clinicians to reinfuse rather than discard the clearing volume. Needleless VAMP systems are designed to reduce infection, needle sticks, and blood waste associated with conventional blood sampling methods.1-4
Safe, simple and reliable closed blood sampling for effective patient blood management.
- VAMP adult system is designed to reduce infection and blood waste associated with traditional blood sampling
- 5 cc reservoir designed for safe and convenient blood sampling in environments where close proximity to the patient is desired
- For use with disposable pressure transducers and for connection to central line catheters and arterial catheters
- Versatile design can be pole mounted on a backplate or used as an arm mount
- Z-site self-sealing sample port reduces blood buildup for collection of undiluted samples and improves infection control compared to traditional sampling methods

Model numbers
Model | Description | Unit of measure |
---|---|---|
48VMP106 | 6" sampling kit, sample site, reservoir and two shut-off valves | CS(20) |
48VMP120 | 20" sampling kit, sample site and arm-mount reservoir | CS(20) |
48VMP160 | 60" sampling kit, sample site and arm-mount reservoir | CS(20) |
48VMP184 | 84" sampling kit, sample site and arm-mount reservoir | CS(20) |
48VMP284 | 84" sampling kit, sample site and pole-mount reservoir | CS(20) |
48AVMP | VAMP system anesthesia kit, 68" sampling kit with male / female connector | CS(20) |
Sampling flexibility between surgery and intensive care
- Large 12 cc reservoir provides optimized clearing volume
- Choice of one or two Z-site sample sites for flexibility in perioperative settings
- Convenient one-handed operation simplifies sampling and clearing volume reinfusion
- For use with disposable pressure transducer kit or for individual connection to central line or arterial catheters

Model numbers
Model | Description | Unit of measure |
---|---|---|
VP1 | VAMP Plus system reservoir with 60" patient tubing and one sample site located 55" from the patient | CS(10) |
VP2 | VAMP Plus system reservoir with 60" patient tubing and two sample sites located 13" and 55" from the patient | CS(10) |
Safety and accuracy for your smallest patients
- Designed to meet the volume-critical requirements of pediatric patients
- Smaller 3 cc reservoir optimizes clearing volumes, providing undiluted, accurate blood samples
- Graduated “cc” markings aid in selecting appropriate clearing volume for each patient
- Special contamination hood helps reduce infection risk
- Variety of tubing lengths to accommodate patient size requirements

Model numbers
Model | Description | Unit of measure |
---|---|---|
VMP306 | 6" kit with 3 cc reservoir and 2 access sites | CS(20) |
VMP406 | 6" kit with 3 cc reservoir and 1 sample site | CS(20) |
VMP426 | 26" kit with 3 cc reservoir and 1 sample site | CS(20) |
Hemodynamic education empowering clinical advancement
With a long-term commitment to improving the quality of care for surgical and critical care patients through education, Edwards clinical education meets you no matter where you are in the learning process — with a continuum of resources and tools that continuously support you as you solve the clinical challenges facing you today, and in the future.
Model numbers
Model | Description | Unit of measure |
---|---|---|
VMP400 | VAMP system needleless cannula | CS(200) |
Related products
The Edwards Advantage
We are committed to providing your institution, clinicians and staff with the highest levels of customer service and support to ensure seamless product implementation and ongoing use, including:
- 24/7 Technical support – Call 800-822-9837 anytime, day or night
- Product information and orders – Call 800-424-3278 to speak to a customer service representative
Thank you
Your information has been submitted. An Edwards representative will contact you shortly.
- Peruzzi, W.T., et al., A clinical evaluation of a blood conservation device in medical intensive care unit patients. Critical care medicine, 1993. 21 (4): p. 501-6
- Oto, J., et al., Comparison of bacterial contamination of blood conservation system and stopcock system arterial sampling lines used in critically ill patients. American Journal of Infection Control, 2012. 40(6): p.530-4
- O'Hare, D. and R.J. Chilvers, Arterial blood sampling practices in intensive care units in England and Wales. Anaesthesia, 2001. 56(6): p. 568-71
- Tang, M., et al,. Closed Blood Conservation Device for Reducing Catheter-Related Infections in Children After Cardiac Surgery. Critical Care Nurse, 2014. 34(5); p.53-61
Important safety information
See Instructions For Use (IFU) / Directions For Use (DFU) for full prescribing information, including indications, contraindications, warnings, precautions and adverse events.
Important safety information
See Instructions For Use (IFU) / Directions For Use (DFU) for full prescribing information, including indications, contraindications, warnings, precautions and adverse events.
Please update your browser
Please update to a current version of your preferred browser, this site will perform effectively on the following:
Unable to update your browser?If you are on a computer, that is maintained by an admin and you cannot install a new browser, ask your admin about it. If you can't change your browser because of compatibility issues, think about installing a second browser for browsing and keep this old one for compatibility