Cosgrove-Edwards annuloplasty system

For preserving natural flexibility, when you want a flexible, open/partial band.

Shape

Open design in the anterior portion of the mitral valve and the septal portion of the tricuspid valve

Open design in the anterior portion of the mitral
               valve and the septal portion of the tricuspid valve

Flexibility

Conforms to 3D annular shape while providing
                support against recurrent dilation

Conforms to 3D annular shape while providing support against recurrent dilation

Fully flexible band

Fully flexible band

Implantability

Commissure markers

Commissure markers

Unique template and lanyard design

Unique template and lanyard design

Three-cut release holder

Three-cut release holder

ModelDescriptionSizesImage
4600 Cosgrove-Edwards annuloplasty-ring 26, 28, 30, 32, 34, 36, 38 mm Cosgrove-Edwards annuloplasty ring
ModelDescriptionSizes
1174 Sizers - Individual 26, 28, 30, 32, 34, 36, 38 mm
TRAY1174 Accessory Tray N/A
1150 Reusable Bendable Handle N/A
1151 Reusable Extended Handle N/A
Physio Flex annuloplasty ring

For remodeling while preserving flexibility, when you want a semi-rigid ring, with an open anterior segment.

Shape

Progressive anterior and posterior saddles mimic
                the native saddle shapes as mitral annular
                dimensions change

Progressive anterior and posterior saddles mimic the native saddle shapes as mitral annular dimensions change

Open anterior segment corresponding to the
                aorto-mitral curtain design to respect the
                native anterior saddle-shape

Open anterior segment corresponding to the aorto-mitral curtain design to respect the native anterior saddle-shape

Flexibility

Designed to preserve physiological annular movement through
(A) progressive in-plane flexibility that increases by size and
(B) greater out-of-plane flexibility (than in-plane)

Designed to preserve physiological annular
                movement

Implantability

Commissure and mid-posterior markers

Commissure and mid-posterior markers

Dedicated sewing cuff and identified suture-zone

Dedicated sewing cuff and identified suture-zone

Single-cut release, bendable holder

Single-cut release, bendable holder

ModelDescriptionSizesImage
5300 Physio Flex annuloplasty ring 24, 26, 28, 30, 32, 34, 36, 38, 40 mm Cosgrove-Edwards annuloplasty ring
ModelDescriptionSizes
1252Sizers Sizers - Individual 24, 26, 28, 30, 32, 34, 36, 38, 40 mm
TRAY1252 Accessory Tray N/A
1150 Reusable Bendable Handle N/A
1151 Reusable Extended Handle N/A
Carpentier-Edwards Physio II annuloplasty ring

For remodeling while preserving flexibility, when you want a semi-rigid, complete ring.

Shape

Anterior saddle and smaller posterior saddle for
                apposition to the aortic root

Anterior saddle and smaller posterior saddle for apposition to the aortic root

Evolves from D-Shape to more circular to
                accomodate the patient with larger leaflet
                tissue and dilated annulus

Evolves from D-Shape to more circular to accomodate the patient with larger leaflet tissue and dilated annulus

Flexibility

Anterior rigidity for remodeling. Posterior
                flexibility for preserving cardiac motion

Anterior rigidity for remodeling. Posterior flexibility for preserving cardiac motion

Implantability

Commissure and mid-posterior markers

Commissure and mid-posterior markers

Dedicated sewing cuff and identified suture zone

Dedicated sewing cuff and identified suture zone

Single-Cut release holder

Single-Cut release holder

ModelDescriptionSizesImage
5200 Carpentier-Edwards Physio II annuloplasty ring 24, 26, 28, 30, 32, 34, 36, 38, 40 mm Carpentier-Edwards Physio II annuloplasty ring
ModelDescriptionSizes
1252 Sizers – Individual 24, 26, 28, 30, 32, 34, 36, 38, 40 mm
TRAY1252 Accessory Tray N/A
1150 Reusable Bendable Handle N/A
1151 Reusable Extended Handle N/A
Carpentier-Edwards Physio annuloplasty ring

For remodeling while preserving flexibility, when you want a semi-rigid, complete ring.

Shape

Anterior saddle shape for apposition of the
                aortic root

Anterior saddle shape for apposition of the aortic root

Restores anatomical size and shape to provide
                optimal orifice area

Restores anatomical size and shape to provide optimal orifice area

Flexibility

Increased posterior flexibility

Increased posterior flexibility

Implantability

2 transverse commissure markers

2 transverse commissure markers

Three-cut release holder

Three-cut release holder

ModelDescriptionSizesImage
4450 Carpentier-Edwards Physio annuloplasty ring 24, 26, 28, 30, 32, 34, 36, 38, 40mm Carpentier-Edwards Physio annuloplasty ring
ModelDescriptionSizes
1174 Sizers – Individual 24, 26, 28, 30, 32, 34, 36, 38, 40 mm
TRAY1174 Sizers - Accessory Tray N/A
1150 Reusable Bendable Handle N/A
1126 Single-Use Sizer Handle N/A
Carpentier-McCarthy-Adams IMR ETlogix
annuloplasty ring

For rigid remodeling, when you want a rigid, complete ring with an asymmetrical design.

Shape

Asymmetrical design to compensate in tethered
                P2/P3 region

Asymmetrical design to compensate in tethered P2/P3 region

Dipped P3 segment to accommodate downward
                displacement of posterior annulus

Dipped P3 segment to accommodate downward displacement of posterior annulus

Flexibility

Rigid ring for complete fixation during cardiac cycle

Rigid ring for complete fixation during cardiac
                cycle

Implantability

Commissure markers

Commissure markers

Dedicated sewing zone

Dedicated sewing zone

Three-cut release holder

Three-cut release holder

P2/P3 segment has increased sewing margin marked
                with dashed

P2/P3 segment has increased sewing margin marked with dashed

ModelDescriptionSizesImage
4100 Carpentier-McCarthy-Adams IMR ETlogix annuloplasty ring 24, 26, 28, 30, 32, 34mm Carpentier-McCarthy-Adams IMR ETlogix annuloplasty ring
ModelDescriptionSizes
1174 Sizers - Individual 24, 26, 28, 30, 32, 34 mm
TRAY1174 Accessory Tray N/A
1150 Reusable Bendable Handle N/A

Important safety information

CAUTION: Federal (United States) law restricts this device to sale by or on the order of a physician.
See Instructions For Use (IFU) / Directions For Use (DFU) for full prescribing information, including indications, contraindications, warnings, precautions and adverse events.

Important safety information

CAUTION: Federal (United States) law restricts this device to sale by or on the order of a physician.
See Instructions For Use (IFU) / Directions For Use (DFU) for full prescribing information, including indications, contraindications, warnings, precautions and adverse events.

Please update your browserClose this window

Please update to a current version of your preferred browser, this site will perform effectively on the following:

Unable to update your browser?

If you are on a computer, that is maintained by an admin and you cannot install a new browser, ask your admin about it. If you can't change your browser because of compatibility issues, think about installing a second browser for browsing and keep this old one for compatibility