Banner image of Mitris Resilia product

Designed to handle the pressure of the mitral position

As your trusted partner in cardiac surgery innovation, Edwards Lifesciences has developed the MITRIS RESILIA mitral valve to help meet the specialized needs of your patients.

Play video MITRIS RESILIA promo animation

When replacement is the best choice, what if you had an option designed to be similar to the native valve?

Created for it

Developed with your patient's quality of life in mind

Picture of patients

Looks like it

A saddle-shaped sewing cuff mimics the native mitral annulus

Picture of Mitris valve

Performs like it

Handles the pressure of the mitral position

Picture of Mitris valve and propeller plane

Key features of the MITRIS valve

Picture of front of Mitris

Built on the Carpentier-Edwards PERIMOUNT valve platform

a platform with over 20 years of published clinical durability.1

Picture of Mitris desmonstrating good visibility

Cobalt chromium bands provide good visibility under fluoroscopy

for easy identification of the landing zone for potential future transcatheter interventions.

Picture of Mitris dry storage

Dry storage

to eliminate need for rinsing.

Picture of front of Mitris demonstrating low profile stents

Lowest profile stents

do not obstruct blood flow through the left ventricular outflow tract (LVOT).

^On a label size 25 mm. Anterior Profile Height.

An enhanced delivery experience

A Posteromedial commissure mark (single black line), an anterolateral commissure mark (double black line), and an anterior segment mark (“A” mark). The black suture markers facilitate the orientation of the valve and help avoid obstruction of the left ventricular outflow tract by stent posts.

Nitinol stents fold down to 55 degrees, allowing for ease of implant; stents return to original position when valve is implanted.

Need more information?

Download the brochure

RESILIA tissue clinical data:

Backed by a strong and growing body of clinical evidence supporting RESILIA tissue’s ongoing study of durability and hemodynamic performance 2, 3, 4, 5

COMMENCE Mitral clinical trial

Clinically stable hemodynamics and one incident of structural valve deterioration (SVD) through 4 years in 82 patients.

98.7% Actuarial freedom from SVD
through 4 years

Stable gradients Mean gradient (mmHg)

graph showing commence clinical trial mitral through 4 years

COMMENCE Aortic clinical trial

Clinically stable hemodynamics and zero SVD through 5 years in 689 patients.

100% Actuarial freedom from SVD
through 5 years*

*1 SVD diagnosed at post-operative day 1848

Stable gradients Mean gradient (mmHg)

graph showing commence clinical trial aortic through 5 years

European Aortic Feasibility trial

Clinically stable hemodynamics and zero SVD through 5 years in 133 patients.

100% Actuarial freedom from SVD
through 5 years

Mean gradient (mmHg) Valve sizes 19-27 mm

graph showing European feasability trial through 5 years

Promising data. Inspiring results.

RESILIA tissue story

Device preparation animation

Play video MITRIS In Service Animation video

References

  1. Bourguignon T, et al. Very long-term outcomes for mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 25-year follow-up of 450 implantations. J Cardiothorac Surg. 2014:148(5):2004-11.
  2. Flameng W, et al. A radomized assessment of an advanced tissue preservation technology in the juvenile sheep model. J Thorac Cardivasc Surg. 2015:149:340-5.
  3. Bartus K, et al. Final 5-year outcomes following aortic valve replacement with a RESILIA tissue bioprosthesis. Eur J Cardiothorac Surg. 2021:59(2):434-41.
  4. Bavaria J, et al. Five-year outcomes of the COMMENCE trial investigating aortic valve replacement with a novel tissue bioprosthesis. Society of Thoracic Surgery, 2021 Annual Meeting
  5. Heimansohn D, et al. Mitral Valve Replacement using a Pericardial Valve with RESILIA Tissue. American Association of Thoracic Surgery, 2021 Annual Meeting.

Indications for use

The MITRIS RESILIA mitral valve, Model 11400M is indicated for the replacement of native or prosthetic mitral heart valves.

Key materials list

  • Valve leaflets: Bovine pericardium
  • Stent: Cobalt-chromium alloy and polyester band with a nitinol wireform
  • Fabric stent covering: Polyester and Polytetrafluoroethylene (PTFE) cloth
  • Valve sewing ring: Silicone rubber

Tissue platform

The MITRIS valve features RESILIA tissue and is treated with a special integrity preservation technology that effectively mitigates free aldehydes while protecting and preserving tissue.

No clinical data are available that evaluate the long term impact of RESILIA tissue in patients.

General product information

  • Storage temperature: 10°C to 25°C
  • Storage: Dry storage
  • Rinse procedure: None required
ModelDescriptionSizesImages
11400M MITRIS RESILIA mitral valve 25, 27, 29, 31, 33 mm Picture of front of Mitris
ModelDescriptionSizes
1173B Barrel Sizers - Individual 25, 27, 29, 31, 33 mm
1173R Replica Sizers - Individual 25, 27, 29, 31, 33 mm
1140M Reusable Handle N/A

The Edwards advantage

We are committed to providing your institution, clinicians and staff with the highest levels of customer service and support to ensure seamless product implementation and ongoing use, including:

technical support icon

24/7 Technical support

800-822-9837
Pproduct information icon

For product information and orders

800-268-3993

Important safety information

Important safety information

MITRIS RESILIA Mitral Valve

Indications: For use in replacement of native or prosthetic mitral heart valves.

Contraindications: There are no known contraindications with the use of the MITRIS RESILIA mitral valve.

Complications and Side Effects: Thromboembolism, valve thrombosis, hemorrhage, hemolysis, regurgitation, endocarditis, structural valve deterioration, nonstructural dysfunction, stenosis, arrhythmia, transient ischemic attack/stroke, congestive heart failure, myocardial infarction, ventricular perforation by stent posts, any of which could lead to reoperation, explantation, permanent disability, and death.

CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. See instructions for use for full prescribing information.

Please update your browserClose this window

Please update to a current version of your preferred browser, this site will perform effectively on the following:

Unable to update your browser?

If you are on a computer, that is maintained by an admin and you cannot install a new browser, ask your admin about it. If you can't change your browser because of compatibility issues, think about installing a second browser for browsing and keep this old one for compatibility