Clot management  Clot management
Count on the experience of the first name in clot management

Fogarty® arterial embolectomy catheter

Removal of fresh, soft emboli and thrombi from vessels in the arteries of the non-central circulatory system

  • Hand-tied using a recessed winding technique to secure balloon to catheter
  • Balloon exhibits a symmetry that exerts uniform contact with vessel walls for even pressure and
    precise traction
  • Rounded tip promotes easy insertion for reduced trauma
Fogarty clot management catheters brochure

Fogarty arterial embolectomy catheters (5 pack)

ModelLength (cm)Catheter Size (F)Inflated Balloon Diameter (mm)Max. Size of Deflated Balloon (F)Max. Gas Capacity (ml)Max. Liquid Capacity (ml)Max. Recommended Pull Force on Inflated Balloon (lbs.)Compatible Guidewire (in.)
120602FP 60 2 4 3.4 0.2 - 0.5 -
120403FP 40 3 5 4.3 0.6 0.20 0.7 -
120403FSP 40 3 5 4.3 0.6 0.20 0.7 -
120803FP 80 3 5 4.3 0.6 0.20 0.7 -
120803FSP 80 3 5 4.3 0.6 0.20 0.7 -
120404FP 40 4 9 5.0 1.7 0.75 1.5 -
120804FP 80 4 9 5.0 1.7 0.75 1.5 -
120805FP 80 5 11 6.0 3.0 1.50 2.0 -
120806FP 80 6 13 7.0 4.5 2.00 2.5 -
120807FP 80 7 14 8.0 5.0 2.50 3.5 -

Edwards Fogarty catheter rack

  • This rack is intended to be wall-mounted
  • After wall-mounting it can be used to hold Fogarty catheters
  • Model number CV6000

Fogarty Fortis arterial embolectomy catheter

Removal of fresh, soft emboli and thrombi from vessels in the arteries of the non-central circulatory system

  • Can withstand greater pull-force than the Fogarty arterial embolectomy catheter
  • The addition of barium sulfate to the catheter tubing provides radiopacity

Fogarty clot management catheters brochure

Fogarty Fortis arterial embolectomy catheter

ModelLength (cm)Catheter Size (F)Inflated Balloon Diameter (mm)Max. Size of Deflated Balloon (F)Max. Gas Capacity (ml)Max. Liquid Capacity (ml)Max. Recommended Pull Force (lbs.)Compatible Introducer (f)Compatible Guidewire (in.)
120404FF 40 4 9 5.0 1.7 0.75 - 5 -
120804FF 80 4 9 5.0 1.7 0.75 - 5 -

Edwards silicone embolectomy catheter

When you are seeking additional solutions for clot management

  • Silicone balloon and catheter body
  • Stainless steel reinforced catheter body
  • Available in tube or flat packaging

Fogarty thru-lumen embolectomy catheter

Multi-use guidewire-compatible design enables removal of fresh, soft emboli and thrombi from vessels in the arterial system as well as temporary occlusion of blood vessels, infusion of fluids, and blood sampling

  • Fogarty balloon conforms to the vessel to maximize clot removal while minimizing trauma
  • Provides the solution for distal thrombus removal in the arterial system
  • The addition of barium* to the catheter shaft material and stainless steel markers proximal and distal to the balloon provide radiopacity
*3F thru-Lumen embolectomy catheter body does not include barium

Fogarty clot management catheters brochure

ModelLength (cm)Catheter Size (F)Inflated Balloon Diameter (mm)Max. Size of Deflated Balloon (F)Max. Gas Capacity (ml)Max. Liquid Capacity (ml)Max. Recommended Pull Force on Inflated Balloon (lbs.)Compatible Introducer* (f)Compatible Guidewire (in.)
12TLW403F 40 3 5 4.5 0.4 0.15 0.7 4.5 0.018
12TLW803F 80 3 5 4.5 0.4 0.15 0.7 4.5 0.018
12TLW1203F 120 3 5 4.5 0.4 0.15 0.7 4.5 0.018
12TLW404F 40 4 9 5.0 1.2 0.50 1.5 5 0.025
12TLW804F 80 4 9 5.0 1.2 0.50 1.5 5 0.025
12TLW405F35 40 5.5 11 6.0 1.7 0.90 2.0 6 0.035
12TLW805F35 80 5.5 11 6.0 1.7 0.90 2.0 6 0.035
12TLW406F 40 6 13 7.0 2.3 1.40 2.5 7 0.035
12TLW806F 80 6 13 7.0 2.3 1.40 2.5 7 0.035
12TLW807F 80 7 14 8.0 2.8 1.60 3.5 8 0.038
*Ease of introducing the catheter through hemostasis valve may vary among manufacturers.

Fogarty Corkscrew catheter

Removal of emboli and thrombi from either native vessels or synthetic grafts in the arterial system

  • For extracting thrombus that is too resistant for an elastomeric balloon
  • Corkscrew design increases the surface area for entrapping fibrous material
  • Radiopaque and flexible
Fogarty clot management catheters brochure Fogarty clot management catheters reference guide
ModelUsable Length (cm)Catheter Size (F)Membrane Diameter Max. Extended (mm)Membrane Diameter Max. Retracted (mm)
140806 80 4 2.7 6
140808 80 5 3.1 8
1408010 80 6 3.3 10

Fogarty graft thrombectomy catheter

Designed for removing organized thrombus and adherent thrombotic material from synthetic bypass grafts, specifically, AV fistulas for dialysis access and grafts for iliofemoral bypass

  • For thrombus too resistant for an elastomeric balloon
  • Provides a larger diameter range than the Fogarty adherent clot catheter
  • The pulling force can be varied by adjusting the diameter
Fogarty clot management catheters brochure Fogarty clot management catheters reference guide
ModelLength (cm)Catheter Size (F)Membrane/Spiral Diameter Max. Extended (mm)Membrane/Spiral Diameter Max. Retracted (mm)
160245F 50 5 5.0 16
160246F 50 6 6.0 18

Fogarty venous thrombectomy catheter

Designed for removing thrombi in the venous system

  • The long, soft tip permits advancement past the venous valves without undue trauma
Fogarty clot management catheters brochure
ModelLength (cm)Catheter Size (F)Inflated Balloon Diameter (mm)Max. Size of Over Deflated Balloon (F)Max. Gas Capacity (ml)Max. Liquid Capacity (ml)Max. Recommended Pull Force (lbs.)Compatible Introducer (f)Compatible Guidewire (in.)
320806F 80 6 12 7.7 3.0 1.50 - - -
320808F 80 8 13 8.8 4.5 2.25 - - -
32080810F 80 8 19 10.0 8.0 4.00 - - -

Related products

Contact Us

The Edwards Advantage

We are committed to providing your institution, clinicians and staff with the highest levels of customer service and support to ensure seamless product implementation and ongoing use, including:

  • 24/7 technical support – Call 800-822-9837 anytime, day or night
  • Product information and orders – Call 1-800-FOGARTY to speak to a customer service representative

Please update your browserClose this window

Please update to a current version of your preferred browser, this site will perform effectively on the following:

Unable to update your browser?

If you are on a computer, that is maintained by an admin and you cannot install a new browser, ask your admin about it. If you can't change your browser because of compatibility issues, think about installing a second browser for browsing and keep this old one for compatibility