ForeSight tissue oximetry system
Absolute measures, comprehensive insights
The right monitoring makes a difference –
for all your patients' differences
The tissue oximetry and advanced haemodynamic insights you need to identify and even reverse cerebral desaturations for a diverse patient population are now available on one monitor.
ForeSight tissue oximetry sensor:
- Accounts for patient-to-patient differences, including skin tone, size, age, scalp-to-cortex distance and acuity
- Delivers absolute StO2 values, making a preinduction baseline optional
- Measures relative change in total tissue haemoglobin, providing insights into causes of StO2 changes
- Integrates with HemoSphere platform for an all-in-one view of patient perfusion
With ForeSight sensor, you can have the actionable tissue oximetry insights you need to intervene when it matters most.
The ForeSight sensor difference
Across a diverse patient population
As part of a complete haemodynamic profile
Designed for patient diversity
A tissue oximetry sensor designed with patient differences in mind
Due to the limitations in some other tissue oximetry sensor designs, patient differences including melanin or bilirubin concentrations, cranial thickness, etc., can cloud the accuracy – and therefore the reliability – of oxygenation measures.
With a unique sensor design and exclusive fifth wavelength of near infrared light (NIRS), ForeSight sensor can account for these patient differences – enabling reliable StO2 measures from patient to patient.
Study shows ForeSight sensor accounts for individual differences in melanin
Figure 1. Preoperative tissue oximetry, Sun et. al.
In conventional two-wavelength tissue oximetry systems, skin pigmentation has been shown to interfere with the clinical measurement of regional cerebral oxygen saturation. (Sun et al.)
Figure 2. ForeSight sensor readings by race, Stannard et. al.
ForeSight tissue oximetry sensor has been demonstrated to accommodate for the melanin present in a patient’s skin because of its fifth wavelength of near infrared light (NIRS). (Stannard et al.)
ForeSight system is designed to penetrate 25% deeper than other technologies
The ForeSight system is designed to penetrate deeper. At 2.5 cm, the ForeSight sensor can provide reliable readings for patients with greater than 2 cm scalp-cortex distance.
Absolute values, actionable insights
Preinduction baseline optional
The realities of the operating room don’t always allow for the opportunity to set a preinduction baseline – but with ForeSight sensor you can start monitoring without delay.
ForeSight sensor provides continuous, absolute StO2 readings without the need for a preinduction baseline – while still giving you the freedom to set treatment thresholds and trend from a patient baseline.
Algorithms tailored to placement on body
ForeSight sensor algorithms are calibrated and validated to both cerebral and somatic regions:
- Cerebral oximetry SctO2 calibrated and validated to SjvO2
- Somatic oximetry SmtO2 calibrated and validated to ScvO2
Additionally, you can view regional oxygenation values specific to sensor location via HemoSphere advanced monitoring platform.
Actionable insights to protect
Because ForeSight sensor integrates with HemoSphere advanced monitoring platform, you get more than numbers – you get comprehensive insights into patient perfusion, as well as the ability to identify the root cause of imbalances.
Cerebral and somatic tissue oxygen desaturations are common
All-in-one monitoring
One monitor, comprehensive insights
Tissue oximetry measures are only one part of a surgical patient’s haemodynamic profile.
That’s why the ForeSight system is available as part of the HemoSphere advanced monitoring platform – making it the only system that allows you to see a comprehensive view of patient perfusion (including pressure, flow and tissue oximetry) on the same monitor.
This “all-in-one” view delivers comprehensive insights into patient perfusion that can help you drill down to identify the root cause of imbalances – enabling you to administer interventions with confidence.
Another parameter available on HemoSphere platform is Hypotension Prediction Index (HPI), available through Acumen HPI software. This predictive software alerts you to the likelihood of a patient trending toward hypotension – may help to prevent or mitigate cerebral desaturations caused by hypotension.
Also available with HemoSphere monitor
Acumen Hypotension Prediction Index (HPI) software
This predictive software alerts you to the likelihood of a patient trending toward hypotension – and may help to prevent or mitigate cerebral desaturations caused by hypotension.
Model Number
Model | Description | Unit |
FSESL | ForeSight Large sensor (≥40 kg) | 20 |
FSESM | ForeSight medium sensor (≥3 kg) | 20 |
FSESS | ForeSight small sensor (<8 kg) | 20 |
FSESNS | ForeSight non-adhesive small sensor (<8 kg) | 10 |
The Edwards Advantage
We are committed to providing your institution, clinicians and staff with the highest levels of customer service and support to ensure seamless product implementation and ongoing use.
Email aunzcu@edwards.com to speak to a customer service representative.
Customer service - AU: 8am to 5pm
Let us help you
CAUTION: For professional use only.
See Instructions for Use for full prescribing information, including indications, contraindications, warnings, precautions and adverse events.
Edwards, Edwards Lifesciences and the stylised E logo are trademarks of Edwards Lifesciences Corporation. All other trademarks are the property of their respective owners. ©2023 Edwards Lifesciences Corporation. All rights reserved. AU-2022-119
Edwards Lifesciences Pty Ltd. 2/40 Talavera Road, Macquarie Park, NSW 2113, Australia.