Edwards Lifesciences Clot Management Edwards Lifesciences Clot Management

CLOT MANAGEMENT

CLOT MANAGEMENT

Count on the experience of the first name in clot management

FOGARTY ® ARTERIAL EMBOLECTOMY CATHETER

Simple, rapid removal of soft, fresh emboli and thrombi from the arterial system

  • Hand-tied using a recessed winding technique to secure balloon to catheter
  • Balloon exhibits a symmetry that exerts uniform contact with vessel walls for even pressure and
    precise traction
  • Soft, rounded tip promotes easy insertion for reduced trauma
Fogarty Clot Management Catheters Brochure

FOGARTY ARTERIAL EMBOLECTOMY CATHETERS (TUBE PACK)

ModelUsable Length (cm)Catheter Size (F)Inflated Balloon Diameter (mm)Max. Size of Deflated Balloon (F)Max. Gas Capacity (ml)Max. Liquid Capacity (ml)Max. Recommended Pull Force (lbs.)Compatible Introducer (f)Compatible Guidewire (in.)
120602F 60 2 4 3.4 0.2 - 0.5 3.5 -
120403F 40 3 5 4.3 0.6 0.20 0.7 4 -
120803F 80 3 5 4.3 0.6 0.20 0.7 4 -
120404F 40 4 9 5.0 1.7 0.75 1.5 5 -
120804F 80 4 9 5.0 1.7 0.75 1.5 5 -
120805F 80 5 11 6.0 3.0 1.50 2.0 6 -
120806F 80 6 13 7.0 4.5 2.00 2.5 7 -
120807F 80 7 14 8.0 5.0 2.50 3.5 8 -

FOGARTY ARTERIAL EMBOLECTOMY CATHETERS (FLAT PACK WITH SYRINGE)

ModelUsable Length (cm)Catheter Size (F)Inflated Balloon Diameter (mm)Max. Size of Deflated Balloon (F)Max. Gas Capacity (ml)Max. Liquid Capacity (ml)Max. Recommended Pull Force (lbs.)Compatible Introducer (f)Compatible Guidewire (in.)
12A0602F 60 2 4 3.4 0.2 - 0.5 3.5 -
12A0403F 40 3 5 4.3 0.6 0.20 0.7 4 -
12A0803F 80 3 5 4.3 0.6 0.20 0.7 4 -
12A0404F 40 4 9 5.0 1.7 0.75 1.5 5 -
12A0804F 80 4 9 5.0 1.7 0.75 1.5 5 -
12A1004F 100 4 9 5.0 1.7 0.75 1.5 5 -
12A0805F 80 5 11 6.0 3.0 1.50 2.0 6 -
12A0806F 80 6 13 7.0 4.5 2.00 2.5 7 -
12A0807F 80 7 14 8.0 5.0 2.50 3.5 8 -

EDWARDS FOGARTY CATHETER RACK

  • This rack is intended to be wall-mounted
  • After wall-mounting it can be used to hold Fogarty catheters
  • Model number CV6000

FOGARTY FORTIS ARTERIAL EMBOLECTOMY CATHETER

Catheter for more aggressive removal of emboli and thrombi from the arterial system

  • Construction and materials designed to be more durable and withstand greater pull-force
  • The addition of barium to the catheter shaft material provides radiopacity

Fogarty Clot Management Catheters Brochure

ModelUsable Length (cm)Catheter Size (F)Inflated Balloon Diameter (mm)Max. Size of Deflated Balloon (F)Max. Gas Capacity (ml)Max. Liquid Capacity (ml)Max. Recommended Pull Force (lbs.)Compatible Introducer (f)Compatible Guidewire (in.)
120404FF 40 4 9 5.0 1.7 0.75 - 5 -
120804FF 80 4 9 5.0 1.7 0.75 - 5 -

EDWARDS SILICONE EMBOLECTOMY CATHETER 

When you are seeking additional solutions for clot management

  • Silicone balloon and catheter body
  • Stainless steel reinforced catheter body
  • Available in tube or flat packaging

latex

Silicone Embolectomy Brochure

Catheter French SizeCatheter Length (cm)Max. Balloon Inflation CapacityApproximate Balloon Diameter (mm)Flat PacksTube PacksFogarty Flat Packs*Fogarty Tube Packs*
2F 40 0.05 ml 4 NL2EMB40 NL2EMB40T None None
2F 60 0.05 ml 4 NL2EMB60 NL2EMB60T 12A0602F 120602F
3F 40 0.10 ml 5 NL3EMB40 NL3EMB40T 12A0403F 120403F
3F 80 0.10 ml 5 NL3EMB80 NL3EMB80T 12A0803F 120803F
4F 40 0.50 ml 9 NL4EMB40 NL4EMB40T 12A0404F 120404F
4F 80 0.50 ml 9 NL4EMB80 NL4EMB80T 12A0804F 120804F
4F 100 0.50 ml 9 NL4EMB100 None 12A1004F None
5F 40 0.75 cm 11 NL5EMB40 NL5EMB40T None None
5F 80 0.75 cm 11 NL5EMB80 NL5EMB80T 12A0805F 120805F
6F 40 1.25 cm 13 NL6EMB40 NL6EMB40T None None
6F 80 1.25 cm 13 NL6EMB80 NL6EMB80T 12A0806F 120806F
7F 40 2.00 cm 14 NL7EMB40 NL7EMB40T None None
7F 80 2.00 cm 14 NL7EMB80 NL7EMB80T 12A0807F 120807F

* The product contains natural rubber latex.

OVER-THE-WIRE FOGARTY THRU-LUMEN EMBOLECTOMY CATHETER

Multi-use, guidewire-compatible design enables removal of soft, fresh emboli and thrombi as well as fluid delivery, temporary occlusion, and blood sampling

  • Tough, compliant Fogarty balloon conforms to the vessel to maximize clot removal while minimizing trauma
  • Provides the solution for distal thrombus removal in the arterial system
  • The addition of barium to the catheter shaft material and stainless steel markers proximal and distal to the balloon provide radiopacity

Fogarty Clot Management Catheters Brochure

ModelUsable Length (cm)Catheter Size (F)Inflated Balloon Diameter (mm)Max. Size of Deflated Balloon (F)Max. Gas Capacity (ml)Max. Liquid Capacity (ml)Max. Recommended Pull Force (lbs.)Compatible Introducer (f)Compatible Guidewire (in.)
12TLW403F 40 3 5 4.5 0.4 0.15 0.7 4.5 0.018
12TLW803F 80 3 5 4.5 0.4 0.15 0.7 4.5 0.018
12TLW1203F 120 3 5 4.5 0.4 0.15 0.7 4.5 0.018
12TLW404F 40 4 9 5.0 1.2 0.50 1.5 5 0.025
12TLW804F 80 4 9 5.0 1.2 0.50 1.5 5 0.025
12TLW405F35 40 5.5 11 6.0 1.7 0.90 2.0 6 0.025
12TLW805F35 80 5.5 11 6.0 1.7 0.90 2.0 6 0.035
12TLW406F 40 6 13 7.0 2.3 1.40 2.5 7 0.035
12TLW806F 80 6 13 7.0 2.3 1.40 2.5 7 0.035
12TLW807F 80 7 14 8.0 2.8 1.60 3.5 8 0.038

FOGARTY ADHERENT CLOT CATHETER

Used to dislodge adherent material in native vessels and synthetic grafts

  • For extracting thrombus that is too resistant for an elastomeric balloon
  • Corkscrew design increases the surface area for entrapping fibrous material
  • Radiopaque and flexible
Fogarty Clot Management Catheters Brochure

ModelUsable Length (cm)Catheter Size (F)Membrane/Spiral Diameter Max. Extended (mm)Membrane/Spiral Diameter Max. Retracted (mm)
140806 80 4 2.7 6
140808 80 5 3.1 8
1408010 80 6 3.3 10

FOGARTY GRAFT THROMBECTOMY CATHETER

Designed for removing organized and adherent  thrombus from synthetic grafts, such as aortofemoral graft

  • For thrombus too resistant for an elastomeric balloon
  • Provides a larger diameter range than the Fogarty adherent clot catheter
  • The pulling force can be varied by adjusting the diameter
Fogarty Clot Management Catheters Brochure
ModelUsable Length (cm)Catheter Size (F)Membrane/Spiral Diameter Max. Extended (mm)Membrane/Spiral Diameter Max. Retracted (mm)
160245F 50 5 5.0 16
160246F 50 6 6.0 18
.

FOGARTY VENOUS THROMBECTOMY CATHETER

Designed for removing thrombi in the venous system

  • The long, soft tip facilitates advancement past the venous valves without undue trauma
Fogarty Clot Management Catheters Brochure

ModelUsable Length (cm)Catheter Size (F)Inflated Balloon Diameter (mm)Max. Size of Deflated Balloon (F)Max. Gas Capacity (ml)Max. Liquid Capacity (ml)Max. Recommended Pull Force (lbs.)Compatible Introducer (f)Compatible Guidewire (in.)
320806F 80 6 12 7.7 3.0 1.50 - - -
320808F 80 8 13 8.8 4.5 2.25 - - -
32080810F 80 8 19 10.0 8.0 4.00 - - -

FOGARTY IRRIGATION CATHETER 

Can be used to heparinize the arterial tree following embolectomy or venous thrombectomy

Fogarty Clot Management Catheters Brochure

ModelUsable Length (cm)Catheter Size (F)Inflated Balloon Diameter (mm)Max. Size of Deflated Balloon (F)Max. Gas Capacity (ml)Max. Liquid Capacity (ml)Max. Recommended Pull Force (lbs.)Compatible Introducer (f)Compatible Guidewire (in.)
220804F 80 4 - - - - - - -
220806F 80 6 - - - - - - -
2202310F 23 10 - - - - - - -

Related Products


The Edwards Advantage

We are committed to providing your institution, clinicians and staff with the highest levels of customer service and support to ensure seamless product implementation and ongoing use, including:

  • 24/7 Technical Support – Simply call 800-822-9837 anytime, day or night
  • Customer Service – Call 800-424-3278 to speak to a customer service representative

Contact a Sales Rep

Please update your browser

Please update to a current version of your preferred browser, this site will perform effectively on the following:

Unable to update your browser?

If you are on a computer, that is maintained by an admin and you cannot install a new browser, ask your admin about it. If you can't change your browser because of compatibility issues, think about installing a second browser for browsing and keep this old one for compatibility